ELECTRONICAL Repair lab · MILANO

Toshiba board repair ESTIA

A Toshiba ESTIA heat pump includes controls that work on the hydraulic circuit and on the outdoor unit. To request repair of a board, you need to distinguish these functions. The database here is ESTIA HWS series 3, documented in manual A10-006-1; it should not be applied automatically to other families Toshiba.

Hydronic module and outdoor unit: two references to be collected

The code E04 in the documented ESTIA family concerns the serial communication between the hydronic and external module. To locate the problem both plates are useful, the command showing the error and identification of the suspect board.

Indicates if the system still produces sanitary water, if the block affects only heating or if all functions are firm. The description of the system allows to connect the alarm to the correct control path, distinguishing a connection problem from an electronic defect.

Water-flow and sensor indications do not prove a board fault

A01 concerns the pump or insufficient water flow. F10 and F11 refer to water input and output probes. These signals require a comparison of hydraulic conditions, sensors and acquisition circuits: the board is not the only possible part of the diagnosis.

Before sending, collect the results of the verifications carried out by the technical on circulation and detection. There is no need for repeated recovery attempts without registering the defect; it is more useful to know at which stage it appears and what conditions have been observed on the plant.

Memory and power: which electronics examine

In the same family, F29 indicates an anomaly EEPROM of the hydronic module, while P26 concerns the compressor’s piloting stage. The two reports refer to functions and boards to be identified separately.

Send photographs of the labels and circuit revision, together with details of any previous replacements or reprogramming. The repair lab assesses the component actually installed and whether it can be repaired and tested. The board reference is also needed for equipment in the same HWS series: the description “Toshiba board” alone does not identify the component to be examined.

Models and references of this guide

HWS-803H-E(TR) · HWS-1103H-E(TR) · HWS-1403H-E(TR) · HWS-1103H8-E · HWS-1103H8R-E · HWS-1403H8-E · HWS-1403H8R-E · HWS-1603H8-E · HWS-1603H8R-E · HWS-803XWHM3-E(TR) · HWS-803XWHT6-E(TR) · HWS-803XWHD6-E · HWS-803XWHT9-E · HWS-1403XWHM3-E(TR) · HWS-1403XWHT6-E(TR) · HWS-1403XWHD6-E · HWS-1403XWHT9-E(TR)

Model and code of PCB must be verified before defining repair. The presence in the list does not guarantee compatibility between boards.

View codes in the correct series

The series in the database

Contact the repair labWe start from the model and problem of your machine

MAKE AN INFORMED CHOICE

Your fault is our starting point.

Discuss the fault directly with us. We assess whether repair is possible and provide a quote before starting. Bench tests are selected to suit the board.

How we assess an electronic board