TECHNICAL DATABASE
ToshibaESTIA HWS series 3 – A10-006-1
53 search entries, with any different interpretations for the same signal.
Reference models
HWS-803H-E(TR) · HWS-1103H-E(TR) · HWS-1403H-E(TR) · HWS-1103H8-E · HWS-1103H8R-E · HWS-1403H8-E · HWS-1403H8R-E · HWS-1603H8-E · HWS-1603H8R-E · HWS-803XWHM3-E(TR) · HWS-803XWHT6-E(TR) · HWS-803XWHD6-E · HWS-803XWHT9-E · HWS-1403XWHM3-E(TR) · HWS-1403XWHT6-E(TR) · HWS-1403XWHD6-E · HWS-1403XWHT9-E(TR)
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| A01 | Insufficient water pump or flow | A1 |
| A02 | Excess temperature of the heating circuit | A2 |
| A03 | Excessive temperature of health storage | A3 |
| A04 | Antifreeze protection of the exchanger | A4 |
| A05 | Antifreeze protection of pipes | A5 |
| A07 | Intervention of the | A7 |
| A08 | Low Pressure Protection Intervention | A8 |
| A09 | Over-temperature protection of auxiliary heater | A9 |
| A11 | Water temperature limiting interventions | A11 |
| A12 | Insufficient heating or sanitary water support | A12 |
| E01 | The command does not receive data from the hydronic module | E1 |
| E02 | Command transmission to the hydronic module | E2 |
| E03 | Periodic communication between hydronic module and absent command | E3 |
| E04 | Hydronic–external serial communication absent | E4 |
| E09 | More remote commands configured as main | E9 |
| F03 | Heat exchanger sensor TC | F3 |
| F04 | Compressor discharge sensor TD | F4 |
| F06 | Outdoor heat exchanger sensor TE | F6 |
| F07 | Outdoor heat exchanger sensor TL | F7 |
| F08 | Outdoor air sensor TO | F8 |
| F10 | Water inlet sensor TWI | F10 |
| F11 | Water outlet sensor TWO | F11 |
| F12 | Suction sensor TS | F12 |
| F13 | Heat sink sensor TH | F13 |
| F14 | Domestic hot water tank sensor TTW | F14 |
| F15 | TE/TS sensors: incorrect connection or installation | F15 |
| F17 | Floor heating circuit inlet sensor TFI | F17 |
| F18 | Heater outlet sensor THO | F18 |
| F19 | THO sensor disconnected or reporting inconsistent values | F19 |
| F20 | Inconsistent TFI sensor readings | F20 |
| F23 | Low pressure sensor | F23 |
| F29 | EEPROM hydronic module | F29 |
| F30 | Integrated Hydronic Module Expansion Circuit | F30 |
| F31 | EEPROM of outdoor unit | F31 |
| H01 | Compressor: anomaly under current control | H1 |
| H02 | Unfinished compressor or starter | H2 |
| H03 | Current Detection Circuit | H3 |
| H04 | Intervention compressor body thermostat | H4 |
| L07 | Group connection of the hydronic module not allowed | L7 |
| L09 | Hydronic module capacity code not set | L9 |
| L10 | Configuration of unset service board | L10 |
| L16 | Zone 2 set without Zone 1 | L16 |
| L29 | Communication between microcontrollers of the eternal | L29 |
| P03 | Too high compressor temperature | P3 |
| P04 | High pressure pressure pressure pressure switch | P4 |
| P05 | Anomalous power voltage | P5 |
| P07 | Overheated inverter diffuser | P7 |
| P15 | Condition compatible with shortage/loss refrigerant | P15 |
| P19 | Four-way valve changeover not confirmed | P19 |
| P20 | High pressure protection via thermal control | P20 |
| P22 | DC outdoor fan fault | P22 |
| P26 | Compressor pilot stage circuit | P26 |
| P29 | Undetected compressor rotor position | P29 |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.