E36 / E 36Excess compressor temperature
SCM ZF – multi-split, manual SCM-T-052
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
SCM60ZF-S · SCM ZF · SKM · STM · SRRM
Reports LED in manual
- RUN: ON · TIMER: 5 — Indoor unit panel during self-diagnosis; ON=fixed light, FLASH=continuous lamp.
What it means
Excess compressor temperature. A temperature outside the normal operating range has been detected. A thermal protection trip does not automatically mean that a circuit board is faulty.
Possible causes to distinguish
- Insufficient cooling.
- Defeated warrant; on the SRK family also closed service valve to be checked.
What to tell the repair lab
Record the full code and photograph the display and the nameplates of the indoor and outdoor units. Tell the laboratory when the shutdown occurs and whether it affects one or more units; avoid repeated restarts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare the measured temperatures with actual operation and the heating/cooling mode.
- The technician checks airflow rates, sensors and the refrigerant circuit according to the product family.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: MHI Inverter Multi Split – Manuale tecnico 06 SCM-T-052 · page 95–96 (PDF97–98).
Contact the repair labThe brand, series and code are already in the message