TECHNICAL DATABASE

Mitsubishi Heavy IndustriesSCM ZF – multi-split, manual SCM-T-052

15 search entries, with any different interpretations for the same signal.

Reference models

SCM60ZF-S · SCM ZF · SKM · STM · SRRM

Code / indicatorMeaningDocumented aliases
E1Communication of the wired commandE 1
E16Internal fan: unconfirmed turnsE 16, RUN-6-TIMER-ON
E36Excess compressor temperatureE 36, RUN-ON-TIMER-5
E37External temperature sensorE 37, RUN-FLASH-TIMER-2
E38External air temperature sensorE 38, RUN-FLASH-TIMER-1
E39Compressor temperature sensorE 39, RUN-FLASH-TIMER-4
E42Protection switch for current compressorE 42, RUN-ON-TIMER-1
E5Communication between indoor and outdoor unitsE 5, RUN-ON-TIMER-6
E53Compressor suction temperature sensorE 53, RUN-FLASH-TIMER-5
E58Stop for limiting currentE 58, RUN-ON-TIMER-3
E59Anomaly starting/commanding the external compressorE 59, RUN-ON-TIMER-2
E6Indoor-unit heat exchanger sensorE 6, RUN-1-TIMER-ON, RUN-5-TIMER-ON, RUN-7-TIMER-ON
E60Compressor block or rotor failureE 60, RUN-2-TIMER-2
E7Internal ambient temperature sensorE 7, RUN-2-TIMER-ON
E9Condensing and floating dischargeE 9, RUN-4-TIMER-ON

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.