E42Current compressor protection
KX/KXR/KXZ – VRF and subcodes
Not all subcodes belong to all generations. E30/E64 are specific KXZW; E36-3 KX6; E44 KXZ; E60 KX4/KX6.
Documented models
KX4 · KXR4 · KX6 · KXR6 · KXZ · KXZP · KXZR · KXZX · KXZRX · KXZW
What it means
Current compressor protection. The electronics interrupts or limits the compressor’s drive to protect it. Diagnosis must involve power, load and power.
Possible causes to distinguish
- Faulty power stage, compressor or associated wiring.
- Power supply or load conditions outside the specified operating conditions.
What to tell the repair lab
Record the full code and photograph the display and the nameplates of the indoor and outdoor units. Tell the laboratory when the shutdown occurs and whether it affects one or more units; avoid repeated restarts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare the time of the protection trip with startup, operating load and other stored alarms.
- The technician checks the compressor and inverter circuit separately, without assuming that the code alone identifies a PCB that needs replacement.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Heavy Industries Service Support Handbook, revisione 18/06/2024 r9 · page 17 (PDF18).
Contact the repair labThe brand, series and code are already in the message