E28Remote control temperature sensor
KX/KXR/KXZ – VRF and subcodes
Not all subcodes belong to all generations. E30/E64 are specific KXZW; E36-3 KX6; E44 KXZ; E60 KX4/KX6.
Documented models
KX4 · KXR4 · KX6 · KXR6 · KXZ · KXZP · KXZR · KXZX · KXZRX · KXZW
What it means
Remote control temperature sensor. The controller is receiving an unreliable measurement; the code alone does not prove that the electronic board is faulty.
Possible causes to distinguish
- Open-circuit sensor or wiring, an intermittent connector, or a short-circuited component.
- Check the board’s sensor input circuit if the sensor and wiring meet specifications.
What to tell the repair lab
Record the full code and photograph the display and the nameplates of the indoor and outdoor units. Tell the laboratory when the shutdown occurs and whether it affects one or more units; avoid repeated restarts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the exact sensor and compare its measured value with the characteristic curve in the manual.
- Check the connectors, continuity and input circuit before attributing the fault to the PCB.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Heavy Industries Service Support Handbook, revisione 18/06/2024 r9 · page 16 (PDF17).
Contact the repair labThe brand, series and code are already in the message