DIAGNOSTIC ENTRY · Mitsubishi Electric

MEM-9Memory or outdoor-unit control

MUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MUZ-EF25VE · MUZ-EF35VE · MUZ-EF42VE · MUZ-EF50VE · MUZ-EF25VEH · MUZ-EF35VEH

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

Memory or outdoor-unit control

Reading conditions: Memory mode: do not use table LED in operation

Indicator light pattern · search label, not an alphanumeric display code

Internal OPERATION indicator:9 lampeggi in fault call

What it means

Memory mode: do not use table LED in operation. The non-volatile memory of external electronics is not read correctly.

Possible causes to distinguish

  • Memory or external control circuit

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check the specific diagnosis of the board without confusing it with a communication error.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 32.

Power module

Reading conditions: Memory mode: do not use table LED in operation

Indicator light pattern · search label, not an alphanumeric display code

Internal OPERATION indicator:9 lampeggi in fault call

What it means

Memory mode: do not use table LED in operation. The control signals the power module or a short in the circuit that feeds the compressor.

Possible causes to distinguish

  • Module IPM
  • Compressor winding or short connection

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Exclude compressor and wiring failures before evaluating the board.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH590B – MUZ-EF25/35/42/50VE(VEH) · page 32.

Contact the repair labThe brand, series and code are already in the message