TECHNICAL DATABASE

Mitsubishi ElectricMUZ-EF25/35/42/50VE(VEH) – LEDs and fault memory

40 search entries, with any different interpretations for the same signal.

Reference models

MUZ-EF25VE · MUZ-EF35VE · MUZ-EF42VE · MUZ-EF50VE · MUZ-EF25VEH · MUZ-EF35VEH

Code / indicatorMeaningDocumented aliases
LED-1Frequency limitation by current—
LED-10Outdoor fan—
LED-11Closed service valve—
LED-12Current detection—
LED-13Bus voltage DC—
LED-14Other external anomaly—
LED-16Four-way valve or pipe temperature—
LED-2Overcurrent protection—
LED-3Limitation by temperature/pressure—
LED-4Limitation by sending temperature—
LED-5High pressure protection—
LED-6Serial communication—
LED-7Temperature too low—
LED-8Converter or correction power factor—
LED-9Test mode or service—
MEM-1Serial communication—
MEM-10Temperature too low—
MEM-11Current detection—
MEM-14Four-way valve or pipe temperature—
MEM-2Outdoor-unit power system—
MEM-3External heaters—
MEM-4Overcurrent protection—
MEM-5High discharge temperature—
MEM-6High pressure protection—
MEM-7Heat sink or board overheating—
MEM-8Outdoor fan—
MEM-9Memory or outdoor-unit control—
MEM-EST-1Probe debriefing—
MEM-EST-11Overcurrent protection—
MEM-EST-12Synchronism or compressor start—
MEM-EST-14Closed service valve—
MEM-EST-16Four-way valve or pipe temperature—
MEM-EST-2External air supply—
MEM-EST-3Heat sink temperature sensor—
MEM-EST-4Supplies temperature board—
MEM-EST-5Memory or outdoor-unit control—
MEM-EST-6Power module—
MEM-EST-7Heat sink or board overheating—
MEM-EST-8Bus voltage DC—
MEM-EST-9Current detection—

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.