222Overcurrent input AC of the inverter board – external slave1
Multi V 5 ARUM – full outdoor-unit display code
Insert the entire number of the external display. The final digit indicates normalmente1=master,2=slave1,3=slave2. Exceptions documentate511/512: two different capacity errors. A logical code CH242 is distinguished from display242 (CH24 out of slave1).
Documented models
ARUM072BTE5 · ARUM072DTE5 · ARUM096BTE5 · ARUM096DTE5 · ARUM121BTE5 · ARUM121DTE5 · ARUM144BTE5 · ARUM144DTE5 · ARUM168BTE5 · ARUM168DTE5 · ARUM192BTE5 · ARUM192DTE5 · ARUM216BTE5 · ARUM216DTE5 · ARUM241BTE5 · ARUM241DTE5
What it means
The complete display 222 identifies the main code CH22 on the outdoor unit slave1. Overcurrent input AC of the inverter board. The electronics interrupts or limits the compressor’s drive to protect it. Diagnosis must involve power, load and power.
Possible causes to distinguish
- Faulty power stage, compressor or associated wiring.
- Power supply or load conditions outside the specified operating conditions.
What to tell the repair lab
Record the full code and photograph the display and the nameplates of the indoor and outdoor units. Tell the laboratory when the shutdown occurs and whether it affects one or more units; avoid repeated restarts.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Compare the time of the protection trip with startup, operating load and other stored alarms.
- The technician checks the compressor and inverter circuit separately, without assuming that the code alone identifies a PCB that needs replacement.
Record the full code and identify the affected outdoor unit; do not omit the address digit.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: LG Multi V 5 Outdoor Unit Service Manual · page 128.
Contact the repair labThe brand, series and code are already in the message