ELECTRONIC SERVICE MILANO ARCHIVE
2P117977-1G, 3PCB1265-1
Board 2P117977-1G, with reference 3PCB1265-1 visible on the circuit board.
ERRORE, CASES AND ELECTRONICAL EVALUATION
Code Daikin U4 indicates a problem with data exchange between the indoor and outdoor units. The FTXTM-A manual describes it as a transmission error between those units. The code identifies the communication problem, but does not automatically identify a faulty board. To establish why the connection is failing, the complete model, symptoms and checks for the installed series are required.
Air conditioning units must exchange data. In the Atmosphera technical manual, U4 appears when the external data is not received correctly or is abnormal. Documented causes include out-of-specific power supply, voltage drops, incorrect or interrupted wiring, board defects and waveform disturbances. For that series it is also indicated a possible short in the fan motor.
This list serves to understand why it is not enough to read U4 and order a PCB. The same signal can have different origins; the hypotheses must be compared with the measurements and the manual of the machine.
In the manual Sky Air RZR/RZQ TAVJUA, U4 concerns transmission between internal and external. The document includes among the possible causes the unpowered outdoor unit, connections anomalies F1/F2, inconsistent system addresses and defects of the internal board or the external main.
These terminals and these procedures belong to the models described by the manual. Do not automatically transfer to another split or VRV. The technical documents mentioned include North American series: illustrate diagnostic differences, without replacing the manual of the installed European model.
The board becomes a possible cause when checks on the system do not explain the problem. The technician must distinguish a missing power supply, a broken connection and an electronic fault. A photograph of the display is useful for opening the case, but cannot prove which component has failed.
For repair lab evaluation, the complete acronym of PCB, the unit model and the test report already performed. Send this information before organizing disassembly or shipment: allow you to assess whether the analysis of the board is relevant to the reported defect.
Picture the accessible code and tags. Note if the block appears immediately on startup or after a period of operation, and if it affects only one unit or more environments. It also signals any electrical interruptions or recent interventions: it is information to check, not a diagnosis.
To read the error memory, use the instructions of your remote control. Not all keystrokes are the same. Do not open the electrical compartments, do not disconnect wiring and do not repeat restarts to hide a persistent alarm. Electrical measurements and circuit tests are the technical.
Electronic Service Milano – Conditioning Division collects your request with brand, error code and machine information. In the message add the photos available and describe the behavior observed. If you are an installer, report the checks already made and the identification of the board. This avoids starting again from the only written U4 and makes the assessment of the case more accurate.
No. The manuals consulted also indicate power and connection problems. The board is one of the possible causes and must be verified in the context of the machine.
If the code temporarily disappears, this does not prove that its cause has been eliminated. Note when it returns and describe the behaviour to the technician.
Full code, internal and external models, photos of the tags, moment of appearance and recent interventions. For the board: identification PCB and tests carried out by the technician.
The guide summarizes the manuals indicated; complete model and machine revision determine the applicability.
This photograph from our archive shows the references on a PCB. Code U4 alone does not identify this circuit: the equipment details and the board reference are required.
View all pictures of the boards in the archive DaikinMAKE AN INFORMED CHOICE
Discuss the fault directly with us. We assess whether repair is possible and provide a quote before starting. Bench tests are selected to suit the board.
How we assess an electronic board