TECHNICAL DATABASE

PanasonicInverter split CS/CU-S18HKH and S24HKH

27 search entries, with any different interpretations for the same signal.

Full HKH manual table. F90 indicates communication between microcontrollers, should not be confused with the definition PFC of other ranges.

Reference models

CS-S18HKH · CU-S18HKH · CS-S24HKH · CU-S24HKH

Code / indicatorMeaningDocumented aliases
F11Cooling/heating switching anomaly—
F90Communication between system control and compressor control—
F91Anomalous operation of the refrigerant circuit—
F93Anomalous rotation of the external compressor—
F95High pressure cooling protection—
F96Surheating power module IPM—
F97External compressor overheating—
F98Total current draw protection—
F99Continuous current peak on the outdoor unit—
H00No anomaly detected—
H11Communication between indoor and outdoor units—
H12Uncorrect combination capacity class—
H14Internal vacuum air temperature sensor—
H15External compressor temperature sensor—
H16Open circuit of external current transformer—
H19Internal fan motor block—
H23Internal temperature sensor—
H25E-Ion device abnormality—
H27External air temperature sensor—
H28External temperature sensor—
H30Discharge temperature sensor—
H33Erroneous connection between indoor and outdoor units—
H38incorrect matching of brand code—
H58Anomalous gas sensor—
H97Outdoor Fan Lock—
H98High pressure protection inner side—
H99Internal antifreeze protection—

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.