DIAGNOSTIC ENTRY · Mitsubishi ElectricLED1-ON-LED2-10Supplies gas tube circuit A
MXZ-3A54/4A71/4A80/5A100VA – LEDs and fault memory
Scope of this diagnostic entryThis information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-3A54VA · MXZ-4A71VA · MXZ-4A80VA · MXZ-5A100VA
The same report has 4 interpretations according to the reading conditions. Compare the indicator light and the state of the car.
Supplies gas tube circuit A
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 10 lampeggi
What it means
Table LED The gas tube probe associated with the A circuit is open or short. 3A54-E1/E2/E3,4A71-E1/E2/E3,4A80-E1; D probe only in variants 4A71-E1/E2/E3 and 4A80-E1.
Possible causes to distinguish
- Indicated circuit heater
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the A circuit and verify the corresponding probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Supplies gas tube circuit B
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 10 lampeggi
What it means
Table LED The gas tube probe associated with the B circuit is open or short. 3A54-E1/E2/E3,4A71-E1/E2/E3,4A80-E1; D probe only in variants 4A71-E1/E2/E3 and 4A80-E1.
Possible causes to distinguish
- Indicated circuit heater
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the B circuit and verify the corresponding probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Supplies gas tube circuit C
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 10 lampeggi
What it means
Table LED The gas tube probe associated with the C circuit is open or short. 3A54-E1/E2/E3,4A71-E1/E2/E3,4A80-E1; D probe only in variants 4A71-E1/E2/E3 and 4A80-E1.
Possible causes to distinguish
- Indicated circuit heater
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the C circuit and verify the corresponding probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Supplies gas tube circuit D
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 10 lampeggi
What it means
Table LED The gas tube probe associated with the D circuit is open or short. 3A54-E1/E2/E3,4A71-E1/E2/E3,4A80-E1; D probe only in variants 4A71-E1/E2/E3 and 4A80-E1.
Possible causes to distinguish
- Indicated circuit heater
- Connector or board input
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Identify the D circuit and verify the corresponding probe.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 127.
Contact the repair labThe brand, series and code are already in the message