DIAGNOSTIC ENTRY · Mitsubishi Electric

MEM-4Overcurrent protection

MXZ-2A30/40/52VA – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MXZ-2A30VA · MXZ-2A40VA · MXZ-2A52VA

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

Overcurrent protection

Reading conditions: Memory mode: distinct from table LED normal

Indicator light pattern · search label, not an alphanumeric display code

Spia OPERATION interna:4 lampeggi in memory recall

What it means

Memory mode: distinct from table LED normal. The current in the power module reaches the protection condition and the compressor stops.

Possible causes to distinguish

  • Compressor current draw
  • Wiring or inverter
  • Free cold conditions

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Distinguish overload, compressor failure and inverter anomalousness.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 121.

Synchronism or compressor start

Reading conditions: Memory mode

Indicator light pattern · search label, not an alphanumeric display code

Spia OPERATION interna:4 lampeggi in memory recall

What it means

Memory mode. The waveform or compressor behaviour is not consistent with the expected drive.

Possible causes to distinguish

  • Compressor or connections
  • Circuit inverter

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check compressor connections and electrical behavior.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 121.

Contact the repair labThe brand, series and code are already in the message
Look up this code in the search toolAll codes for this seriesMitsubishi Electric electronic board repair