LED1-ON-LED2-2Outdoor-unit power system
MXZ-2A30/40/52VA – LEDs and fault memory
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-2A30VA · MXZ-2A40VA · MXZ-2A52VA
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 steady red; LED2 yellow 2 lampeggi
What it means
Table LED in operation: fixed units or repeated stops. The compressor does not regularly complete the start or repeatedly intervene the power protections.
Possible causes to distinguish
- Compressor or inverter
- Compressor cabling
- Valves and operating conditions
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Examine load, connections and inverter circuit following the diagnostic sequence of the manual.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 125.