LED1-4-LED2-OFFHeat sink or board overheating
MXZ-2A30/40/52VA – LEDs and fault memory
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-2A30VA · MXZ-2A40VA · MXZ-2A52VA
Reading conditions: Table LED in operation: fixed units or repeated stops
Indicator light pattern · search label, not an alphanumeric display code
LED1 red 4 lampeggi; LED2 yellowish
What it means
Table LED in operation: fixed units or repeated stops. The electronics detects excessive temperature on the heatsink or on the board.
Possible causes to distinguish
- Insufficient air flow
- Outdoor fan
- Dissipation or thermal detection
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Check ventilation and thermal readings of the power circuit.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB377H – MXZ-2A/3A/4A/5AVA · page 125.
Contact the repair labThe brand, series and code are already in the message