LED1-2-LED2-OFFOvercurrent protection
MXZ-A26/32WV – pair of outdoor-unit LEDs
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MXZ-A26WV · MXZ-A32WV
Reading conditions: Unit stopped or repeated shutdowns
Indicator light pattern · search label, not an alphanumeric display code
LED1 red 2 lampeggi; LED2 yellowish
What it means
Fixed units or repeated shutdowns. The current in the power module reaches the protection condition and the compressor stops.
Possible causes to distinguish
- Compressor current draw
- Wiring or inverter
- Free cold conditions
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Distinguish overload, compressor failure and inverter anomalousness.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OB319A – MXZ-A14/18/26/32WV · page 55.