MEM-EST-10Overcurrent protection
MUZ-HC25/35VA(VAB) – LEDs and fault memory
This information applies to the specified product family. Confirm the full model and manual revision.
Documented models
MUZ-HC25VA · MUZ-HC35VA · MUZ-HC35VAB
Reading conditions: External detail in memory mode; different from normal LED signal
Indicator light pattern · search label, not an alphanumeric display code
LED outdoor:10 lampeggi beds in fault call procedure
What it means
External detail in memory mode; different from normal LED signaling. The current in the power module reaches the protection condition and the compressor stops.
Possible causes to distinguish
- Compressor current draw
- Wiring or inverter
- Free cold conditions
What to tell the repair lab
Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.
Technical guidance
Guidance for qualified personnel, to be checked against the unit’s service manual.
- Distinguish overload, compressor failure and inverter anomalousness.
Does this necessarily mean the board is faulty?
The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.
Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 28.
Contact the repair labThe brand, series and code are already in the message