DIAGNOSTIC ENTRY · Mitsubishi Electric

LED-3High discharge temperature

MUZ-HC25/35VA(VAB) – LEDs and fault memory

Scope of this diagnostic entry

This information applies to the specified product family. Confirm the full model and manual revision.

Documented models

MUZ-HC25VA · MUZ-HC35VA · MUZ-HC35VAB

The same report has 2 interpretations according to the reading conditions. Compare the indicator light and the state of the car.

High discharge temperature

Reading conditions: Repeated stop and restart

Indicator light pattern · search label, not an alphanumeric display code

LED External Board:3 lampeggi with pause 2,5 seconds

What it means

Stop and restart repeated. The output temperature activates the protection of the compressor.

Possible causes to distinguish

  • Circulating or cooling quantity
  • Expansion valve
  • Reading temperature

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Compare send probe and conditions of the refrigerant circuit.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 29.

Limitation by temperature/pressure

Reading conditions: Unit running

Indicator light pattern · search label, not an alphanumeric display code

LED External Board:3 lampeggi with pause 2,5 seconds

What it means

Unit in operation. Control reduces frequency to prevent high pressure or freezing, according to mode. It does not automatically indicate a failed board.

Possible causes to distinguish

  • Thermal exchange or operating conditions

What to tell the repair lab

Photograph the fault indication and the nameplate. Tell the laboratory when the shutdown occurs and whether it recurs. Checks on circuit boards, wiring and the refrigerant circuit require a qualified technician.

Technical guidance

Guidance for qualified personnel, to be checked against the unit’s service manual.

  • Check mode, temperature and air flow.

Does this necessarily mean the board is faulty?

The code indicates a condition detected by the control. Before evaluating the electronic repair, it is necessary to distinguish the circuit concerned, the connections and operating conditions. Model and description of the defect allow the repair lab to evaluate the case.

Source for this interpretation: Mitsubishi Electric OBH467B – MUZ-HC25/35VA(VAB) · page 29.

Contact the repair labThe brand, series and code are already in the message
Look up this code in the search toolAll codes for this seriesMitsubishi Electric electronic board repair