TECHNICAL DATABASE
LGAS-W DH0/GH0 – flashing-indicator diagnostics
9 search entries, with any different interpretations for the same signal.
Codes documentati1,2,4,5,6,7,8,9,10. Il3 is mentioned only in a note of restoration, without definition: not invented.
Reference models
AS-W0964DH0 · AS-W1264DH0 · AS-W1865DH0 · AS-W0964GH0 · AS-W1264GH0 · AS-W1224DH0 · AS-W1424DH0 · AS-W1825DH0
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| 1 | Interrupted or short | 1 lampeggi, LED-1 |
| 10 | Probe tube sent compressor interrupted or short | 10 lampeggi, LED-10 |
| 2 | Outer probe interrupted or short | 2 lampeggi, LED-2 |
| 4 | High dissipation temperature or anomaly dissipator probe | 4 lampeggi, LED-4 |
| 5 | Communication between indoor and outdoor units | 5 lampeggi, LED-5 |
| 6 | Continuous current peak | 6 lampeggi, LED-6 |
| 7 | Overcurrent CT2 | 7 lampeggi, LED-7 |
| 8 | Internal fan lock BLDC | 8 lampeggi, LED-8 |
| 9 | External blower block BLDC | 9 lampeggi, LED-9 |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.