HisenseAS-18UR4STVUH1 – display codes and LEDs

41 search entries, with any different interpretations for the same signal.

Table LED row numbers are not display codes. The codice2 is the temperature compressor sensor; il13 is the temperature protection sent.

Reference models

AS-18UR4STVUH1

Code / indicatorMeaningDocumented aliases
0No fault detected—
1Outdoor heat exchanger temperature sensor—
10Switching valve four abnormal ways—
11Memory EEPROM anomaly external—
13High temperature protection compressor—
14External air temperature sensor—
15Compressor enclosure temperature control—
16Antifreeze or overload control—
18Missed compressor starter DC—
19Compressor DC out synchronism—
2Compressor temperature sensor—
3Anomalous voltage detection—
33Internal ambient temperature sensor—
34Internal battery temperature sensor—
36Communication between indoor and outdoor units—
39Anomalous internal blower operation—
4Anomalous current transformer—
40Grid protection alarm, column version—
41Passage detection abnormality for zero—
5Power module protection IPM—
6Overvoltage or undervoltage protection—
7Anomalous communication—
8Overload current protection—
9Maximum current control—
LED-000No anomaly, LED external offLED2 0 LED3 0 LED4 0
LED-001Internal or related circuit environment sensorLED2 0 LED3 0 LED4 1
LED-00FAnomaly indoor/outdoor communicationLED2 0 LED3 0 LED4 F
LED-010Internal or related circuit exchange sensorLED2 0 LED3 1 LED4 0
LED-01FExcess compressor enclosure temperatureLED2 0 LED3 1 LED4 F
LED-0F0Protection IPMLED2 0 LED3 F LED4 0
LED-0F1Excess compressor temperatureLED2 0 LED3 F LED4 1
LED-0FFAnomalous indoor fan motorLED2 0 LED3 F LED4 F
LED-100Compressor sensor or related circuitLED2 1 LED3 0 LED4 0
LED-101External or related circuit sensorLED2 1 LED3 0 LED4 1
LED-110External or related air sensorLED2 1 LED3 1 LED4 0
LED-111Anomaly external memoryLED2 1 LED3 1 LED4 1
LED-11FOvervoltage/undervoltage protectionLED2 1 LED3 1 LED4 F
LED-1F0Overload current protectionLED2 1 LED3 F LED4 0
LED-1F1Maximum current controlLED2 1 LED3 F LED4 1
LED-F0FCompressor DC out synchronismLED2 F LED3 0 LED4 F
LED-FF0Compressor DC does not startLED2 F LED3 F LED4 0

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.