TECHNICAL DATABASE

HaierForward HSU09/12/18/24VHJ(DB)

20 search entries, with any different interpretations for the same signal.

Four sections in the PDF, HSU12/18 repeated. Same table di21 entries; codesF added as aliases only if explicit in the backgrounds.

Reference models

HSU09VHJ(DB) · HSU12VHJ(DB) · HSU18VHJ(DB) · HSU24VHJ(DB)

Code / indicatorMeaningDocumented aliases
E1Internal ambient temperature sensor—
E14Anomalous indoor fan motor—
E2Internal temperature sensor—
E4Memory EEPROM internal—
E7Communication between indoor and outdoor unitsLED1-15, LED1 15 lampeggi
LED1-1Memory EEPROM externalLED1 1 lampeggi, F12
LED1-10Temperature sensor defrostingLED1 10 lampeggi, F21
LED1-11Suction temperature sensorLED1 11 lampeggi, F7
LED1-12External ambient temperature sensorLED1 12 lampeggi, F6
LED1-13Discharge temperature sensorLED1 13 lampeggi, F25
LED1-18Anomalous compressor operationLED1 18 lampeggi, F11
LED1-19Anomalous compressor detection circuitLED1 19 lampeggi, F28
LED1-2Protection IPMLED1 2 lampeggi, F1
LED1-24Overcurrent compressorLED1 24 lampeggi
LED1-25Overcurrent on compressor phaseLED1 25 lampeggi
LED1-3Power overcurrent ACLED1 3 lampeggi
LED1-4Communication between IPM and external boardLED1 4 lampeggi, F3
LED1-6Too high or low power supplyLED1 6 lampeggi, F19
LED1-8Excess temperature protectionLED1 8 lampeggi, F4
LED1-9Anomaly external fanLED1 9 lampeggi

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.