TECHNICAL DATABASE
HaierAdvanced AW/1U ES2VHA
22 search entries, with any different interpretations for the same signal.
Display codes and corresponding flashes LED1 of the Advanced series.
Reference models
AW09ES2VHA · AW12ES2VHA · AW18ES2VHA · AW24ES2VHA · 1U09ES2VHA · 1U12ES2VHA · 1U18ES2VHA · 1U24ES2VHA
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| E1 | Internal ambient temperature sensor | — |
| E14 | Anomalous indoor fan motor | — |
| E2 | Internal temperature sensor | — |
| E4 | Memory EEPROM internal | — |
| E7 | Communication between indoor and outdoor units | LED1-15, LED1 15 lampeggi |
| F1 | Module protection IPM | LED1-2, LED1 2 lampeggi |
| F11 | Operation compressor out normal condition | LED1-18, LED1 18 lampeggi |
| F12 | Memory EEPROM external | LED1-1, LED1 1 lampeggi |
| F19 | Power voltage too high or low | LED1-6, LED1 6 lampeggi |
| F2 | Overcurrent compressor | LED1-24, LED1 24 lampeggi |
| F21 | Temperature sensor defrosting | LED1-10, LED1 10 lampeggi |
| F22 | Overcurrent power protection AC | LED1-3, LED1 3 lampeggi |
| F23 | Overcurrent protection on compressor phase | LED1-25, LED1 25 lampeggi |
| F25 | Discharge temperature sensor | LED1-13, LED1 13 lampeggi |
| F27 | Locked compressor roll or momentary stop | LED1-7, LED1 7 lampeggi |
| F28 | Anomalous compressor detection circuit | LED1-19, LED1 19 lampeggi |
| F3 | Communication between IPM and external board | LED1-4, LED1 4 lampeggi |
| F36 | Intermediate temperature sensor capacitor | LED1-39, LED1 39 lampeggi |
| F4 | Excess temperature protection | LED1-8, LED1 8 lampeggi |
| F6 | External ambient temperature sensor | LED1-12, LED1 12 lampeggi |
| F7 | Suction temperature sensor | LED1-11, LED1 11 lampeggi |
| F8 | Anomaly external fan DC | LED1-9, LED1 9 lampeggi |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.