Haier1U48LS/IS and 1U60LS EAB – dedicated table
15 search entries, with any different interpretations for the same signal.
Models as shown in Table pagina19 header. Not confondere42 high pressure con44 of the ERA/ERB table.
Reference models
1U48LS1EAB · 1U48IS1EAB · 1U60LS1EAB
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| 1 | Memory EEPROM abnormal | — |
| 10 | Anomalous sprinkling probe or too high temperature | — |
| 11 | Anomalous suction temperature sensor | — |
| 12 | Anomalous ambient temperature sensor | — |
| 13 | Anomalous temperature sensor | — |
| 15 | Communication with abnormal indoor units | — |
| 16 | Insufficient refrigerant protection | — |
| 17 | Switching valve four abnormal ways | — |
| 25 | Insufficient compressor current or unbalanced phases | — |
| 3 | Overcurrent compressor or incorrect phase sequence | — |
| 42 | High pressure pressure pressure pressure switch | — |
| 43 | Low pressure pressure pressure pressure switch | — |
| 6 | Power voltage too high or low | — |
| 8 | High temperature protection compressor | — |
| 9 | Blower DC anomalous | — |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.