TECHNICAL DATABASE
DaikinSplit / Multi Split
32 search entries, with any different interpretations for the same signal.
Guidance table retained from the previous release: check the full model and subcode. It does not cover every historical unit.
| Code / indicator | Meaning | Documented aliases |
|---|---|---|
| A1 | Anomaly EEPROM / PCB indoor unit | — |
| A5 | Intervention antifreeze protection or limitation temperature internal heat exchanger | — |
| A6 | Anomaly motor internal fan | — |
| A9 | Anomaly internal electronic expansion valve | — |
| C9 | Anomaly thermal environment | — |
| CE | Thermal anomaly radiant panel / dedicated sensor | — |
| E1 | Anomaly PCB outdoor unit | — |
| E5 | Intervention overload compressor protection | — |
| E6 | Compressor block | — |
| E7 | External fan motor block | — |
| EA | Four-way valve anomaly | — |
| F3 | Anomalous temperature control pipe | — |
| F6 | High pressure in cooling | — |
| F8 | Anomalous compressor internal temperature | — |
| H0 | Error H0 – Anomalous compressor sensor system | — |
| H1 | Anomalous moisturizer | — |
| H3 | High pressure pressure dianomy | — |
| H5 | Anomalia termistore protection motor compressor | — |
| H6 | Error H6 – Compressor position detection fault | — |
| H8 | Compressor current detection fault (CT) | — |
| H9 | Anomaly termistore external temperature | — |
| HC | Water temperature sensor | — |
| J3 | Anomaly termistore mandata tube | — |
| J6 | Anomaly thermal heat exchanger external | — |
| L3 | Anomalous temperature electrical components | — |
| L4 | Increase radiant fin temperature | — |
| L5 | Outgoing overcurrent detection | — |
| P4 | Anomalous radiant fin thermal | — |
| P8 | Error P8 – Meaning dependent on the family Daikin | — |
| U0 | Low refrigeration | — |
| U2 | Anomalous supply voltage detection | — |
| U4 | Error U4 – Communication between the indoor and outdoor units | — |
No entries match the filter.
Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.