TECHNICAL DATABASE

DaikinSplit / Multi Split

32 search entries, with any different interpretations for the same signal.

Guidance table retained from the previous release: check the full model and subcode. It does not cover every historical unit.

Code / indicatorMeaningDocumented aliases
A1Anomaly EEPROM / PCB indoor unit—
A5Intervention antifreeze protection or limitation temperature internal heat exchanger—
A6Anomaly motor internal fan—
A9Anomaly internal electronic expansion valve—
C9Anomaly thermal environment—
CEThermal anomaly radiant panel / dedicated sensor—
E1Anomaly PCB outdoor unit—
E5Intervention overload compressor protection—
E6Compressor block—
E7External fan motor block—
EAFour-way valve anomaly—
F3Anomalous temperature control pipe—
F6High pressure in cooling—
F8Anomalous compressor internal temperature—
H0Error H0 – Anomalous compressor sensor system—
H1Anomalous moisturizer—
H3High pressure pressure dianomy—
H5Anomalia termistore protection motor compressor—
H6Error H6 – Compressor position detection fault—
H8Compressor current detection fault (CT)—
H9Anomaly termistore external temperature—
HCWater temperature sensor—
J3Anomaly termistore mandata tube—
J6Anomaly thermal heat exchanger external—
L3Anomalous temperature electrical components—
L4Increase radiant fin temperature—
L5Outgoing overcurrent detection—
P4Anomalous radiant fin thermal—
P8Error P8 – Meaning dependent on the family Daikin—
U0Low refrigeration—
U2Anomalous supply voltage detection—
U4Error U4 – Communication between the indoor and outdoor units—

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.