TECHNICAL DATABASE

DaikinAltherma 3 R F

54 search entries, with any different interpretations for the same signal.

Guidance table retained from the previous release: check the full model and subcode. It does not cover every historical unit.

Code / indicatorMeaningDocumented aliases
7H-01Water flow problem in the hydraulic circuit—
7H-04Water flow problem during hot water production—
7H-05Water flow problem during heating or sampling—
7H-06Water flow problem during cooling or debrining—
80-01Return water temperature sensor problem—
81-00Output water temperature sensor problem—
89-01Antifreeze protection switched on during debriation—
89-02Antifreeze protection during heating or production ACS—
89-03Notice antifreeze protection exchanger during debriation—
89-05Antifreeze protection during cooling—
89-06Warning antifreeze protection during cooling—
8F-00Anomalous increase in output water temperature during production ACS—
8H-00Anomalous water temperature rise—
8H-01Surheating mixed water circuit—
8H-02Surheating mixed water circuit detected by thermostat—
8H-03Surheating water circuit detected by the thermostat—
A1-00Zero-cross detection problem—
A5-00Intervention high pressure protection or antifreeze protection—
AA-01Reserve heater overheating—
AC-00Surheating booster heater—
AH-00Tank disinfection function not completed properly—
AJ-03Excessive time for heating hot water sanitary—
C0-00Anomalous flow sensor—
C4-00Problem sensor temperature exchanger—
C5-00Anomaly termistore exchanger—
CJ-02Ambient temperature sensor problem—
E1-00Anomaly PCB outdoor unit—
E2-00Dispersion Current Detection Error—
E3-00High pressure pressure pressure pressure switch—
E3-24High pressure pressure dianomy—
E4-00Anomaly intake pressure—
E5-00Overheating inverter compressor motor—
E6-00Anomaly start compressor—
E7-00Anomaly external fan motor—
E8-00Overvoltage input power supply—
EA-00Anomaly switching cooling/heating—
F3-00Anomaly temperature mandata tube—
F6-00Anomalous high pressure in cooling—
H0-00Voltage/current sensor problem—
H3-00High pressure pressure dianomy—
H6-00Anomaly sensor location detection—
H8-00Compressor current detection system fault (CT)—
H9-00Anomaly termistore temperature outdoor air—
J3-00Anomaly termistore mandata tube—
J5-00Anomaly termistore suction tube—
J6-07Anomaly termistore external exchanger—
J8-00Liquid Coolant Thermostore anomaly—
JA-00Anomalous high pressure sensor—
L1-00Anomaly PCB inverter—
L3-00Increased electrical panel temperature outdoor unit—
UA-16Internal/outdoor unit matching problem—
UA-17Anomaly communication extension/idrobox—
UA-21Incompatibility between extension and hydronic unit—
UF-00Detecting inverted pipes or incorrect communication wiring—

Items LED and MEM describe faulty indicator lights and memory; they are not display codes. The operating conditions in the manual remain decisive.